CALL US
0086-371-60922096

aashto specification for batch type concrete mixers

Bureau of Materials and Physical Research Standard Method

5.3 Mixing Mix the concrete according to Illinois Modified AASHTO R 39. 5.4 Testing 5.4.1 Slump- Immediately after mixing, measure the slump of each batch of concrete according to Illinois Modified AASHTO T 119. 5.4.2 Air Content- Immediately after mixing, measure the …

Learn More

CITY OF EDMOND STANDARD SPECIFICATIONS FOR …

agent and amounts of mixing water to produce a concrete of satisfactory consistency and air content. D. Tests. Slump will be determined using AASHTO T 119, and air content using AASHTO T 121, AASHTO T 152 or AASHTO T 196 as appropriate. Test specimens will be made and cured in accordance with AASHTO T 23 except

Learn More

DIVISION 1400 CONCRETE ADMIXTURES AND CURING …

This specification covers admixtures for use as air-entraining agents to be added to concrete mixtures. An air-entraining agent is defined as an admixture that is used as an ingredient of concrete, added to the batch immediately before or during mixing, for the purpose of entraining air. An admixture that accelerates the setting of concrete

Learn More

astm specifications for concrete batching plants

Liming Standard Specification for Concrete Made by Volumetric Batching and Continuous Mixing 1.1 This specification covers concrete made from materials continuously Liming The minimum volume of the batcher in m3(ft3),calculated from dimensioned drawings, shall be 0.09m3 (3 ft3) to allow for fluffing and variations in filling,plus 1/3 of

Learn More

DIVISION 1400 CONCRETE ADMIXTURES AND CURING …

This specification covers admixtures for use as air-entraining agents to be added to concrete mixtures. An air-entraining agent is defined as an admixture that is used as an ingredient of concrete, added to the batch immediately before or during mixing, for the purpose of entraining air. An admixture that accelerates the setting of concrete

Learn More

Attachment A - Recommended Changes to AASHTO LRFD Bridge

A.2.4 Production, Handling, and Placement Clause 8.5.4 Batching and Mixing Concrete Clause 8.5.4.1 Batching The size of the batch shall not exceed the capacity of the mixer as guaranteed by the Manufacturer or as determined by the Standard Requirements of the Associated General Con- tractors of …

Learn More

SECTION 406 ASPHALTIC CONCRETE 406-1 Description

Type Specification Portland Cement, Type I, II, III Air-Entraining Portland Cement ASTM C 150, AASHTO M 85 AASHTO M 134 A. Cement used in concrete work will be Portland cement conforming to the requirements of Table 600-1. In general, Type II or IIA shall be used in concrete which shall be in contact with the soil, unless otherwise

Learn More

PCC Truck Mixer – Pavement Interactive

Fly ash shall meet the requirements of AASHTO M-295 for Portland Cement Concrete. Fly Ash will be allowed as a cement replacement on a 1:1 ratio, up to a maximum of 30% by weight. Fly ash content of mixes will be reduced to a maximum of 20% replacement of cement in cold weather concrete conditions.

Learn More

(PDF) Standard Specification for Ready-Mixed Concrete 1

(The purchaser shall inform the producer as to the type 13.1.5 Name of purchaser, of construction for which the concrete is intended.) 13.1.6 Specific designation of job (name and location), Minimum Concrete Temperature as Placed 13.1.7 Specific class or designation of the concrete in Section Size, in. [mm] Temperature, min, °F [C] conformance

Learn More

3 Concrete Job Control - IN.gov

1) AASHTO T 152 - Air Meter and Unit Weight Containers 2) ITM 902 – Sieves 3) ITM 903 – Ovens 4) ITM 910 – Electronic Balances 5) ITM 911 - Slump Cones REFENCED DOCUMENTS ITM and AASHTO test methods are used for concrete job control. INDOT Specifications contain several exceptions to the AASHTO test methods. If

Learn More

SECTION 600 - CONCRETE WORK TABLE OF CONTENTS PAGE

Batching, Mixing, Transporting, and Handling Concrete

Learn More

DIVISION 1400 CONCRETE ADMIXTURES AND CURING …

This specification covers admixtures for use as air-entraining agents to be added to concrete mixtures. An air-entraining agent is defined as an admixture that is used as an ingredient of concrete, added to the batch immediately before or during mixing, for the purpose of entraining air. An admixture that accelerates the setting of concrete

Learn More

Batching, Mixing, Transporting, and Handling Concrete

685 or AASHTO M 241) is used for concrete mixed in con-tinuous mixers. Specifications generally require that materials be measured for individual batches within the following CHAPTER 10 Batching, Mixing, Transporting, and Handling Concrete percentages of accuracy: cementitious material ±1%, aggregates ± 2%, water ±1%, and admixtures ± 3%.

Learn More

SECTION 509 - PORTLAND CEMENT CONCRETE PAVEMENT, …

Jun 01, 2021 · Kefid 509-R-722 3 of 15 C Concrete beams and cylinders cast for the purpose of evaluating the mix criteria shall be cured in accordance with AASHTO T 23 Section 10.1, Standard Cure conditions. D The maximum allowable shrinkage will only apply if the Contractor requests to omit tooling as part of re -establishing the longitudinal joint

Learn More

Section 450 Pressure Grouting Portland Cement Concrete

Jan 01, 2013 · specification for reinforced concrete d-load culvert, storm drain, and sewer pipe: aashto m 170 : 2015 : specification for reinforced concrete culvert, storm drain, and sewer pipe: aashto m 86m/m 86 : 0 : specification for nonreinforced concrete sewer, storm drain, and culvert pipe: aashto m …

Learn More

PART 02000 - MATERIALS Concrete Materials and Additives

Simulate haul time and mixing conditions to ensure proper workability at the jobsite. (b) Plastic Concrete - For each trial batch, test the temperature, slump, density, and air content, and compute the w/cm ratio and yield according to the following tests methods: Test Test Method Sampling Fresh Concrete WAQTC TM 2 Slump AASHTO T 119

Learn More

SECTION 406 ASPHALTIC CONCRETE 406-1 Description

Oct 31, 2019 · Asphaltic concrete shall be produced in a batch mixing plant, a continuous pugmill mixing plant or a drum drier mixing plant. Proportioning shall be either by hot-feed control or cold-feed control. 406-2 Materials 406-2.01 General. The contractor shall obtain Agency approval of materials before any material is mixed at any plants.

Learn More

6-02.3(2)A1 Concrete Class 4000D Mix Design Checklist

the air void system of the hardened concrete has not been adversely affected? f. Type S Specific Performance Admixture 9-23.6(9) 1. Does the mix design indicate the use of a Type S Admixture? If "No" here proceed to No. 16. 2. Is the Type S Admixture being used for either ASR-mitigating,

Learn More

AASHTO M 157 : 2013 SPECIFICATION FOR READY-MIXED …

Batching, Mixing, Transporting, and Handling Concrete

Learn More

Section 3 Specification 3.9 TABLE OF CONTENTS

by changes in the mixing properties of the material being mixed. 3.9.3.3 Batch Type Mixers If a batch type mixer is used, the material shall be proportioned by batch weights. 3.9.3.4 Continuous Type Mixers If a continuous type of mixer is used, the materials shall be proportioned by volume. The sand or gravel

Learn More